• DocumentCode
    2071670
  • Title

    Characterization of the electromagnetic environment in a hospital

  • Author

    Lauer, Oliver ; Riederer, Markus ; Karoui, Naceur ; Vahldieck, Rudiger ; Keller, Emanuela ; Frohlich, Jurg

  • Author_Institution
    Lab. for Electromagn. Fields & Microwave Electron., Swiss Fed. Inst. of Technol. Zurich, Zurich
  • fYear
    2008
  • fDate
    19-23 May 2008
  • Firstpage
    474
  • Lastpage
    477
  • Abstract
    The electromagnetic environment in a hospital is characterized in order to evaluate the conditions for failsafe operation of critical electronic equipment. Field strengths within the University Hospital Zurich were measured at more than 60 different locations in the frequency range from 9 kHz up to 10 GHz. To account for variations in both, time and location, dasiastationary short termpsila and dasiastationary long termpsila measurements over 24 h were carried out. The measurement uncertainty of the measurement equipment, calibration and measurement procedure is assessed. Measurement results are evaluated with respect to given immunity levels (EMC) and in-band interferences (EMI). The ISM band features a noise power density of -32 dBm/MHz while for ultra wide band (UWB) there are different sub-bands with a maximum noise power density of less than -81 dBm/MHz. This suggests that communication in the UWB band requires significantly lower power levels than communication in the ISM band for equal dynamic ranges of the radio links.
  • Keywords
    electromagnetic compatibility; electromagnetic fields; electromagnetic interference; field strength measurement; hospitals; radio links; ultra wideband communication; EM field strength; EMC immunity levels; EMI; UWB communication; University Hospital Zurich; electromagnetic environment; frequency 9 kHz to 10 GHz; hospital; in-band interferences; noise power density; radio links; time 24 h; Calibration; Electromagnetic compatibility; Electromagnetic interference; Electromagnetic measurements; Electronic equipment; Frequency measurement; Hospitals; Measurement uncertainty; Time measurement; Ultra wideband technology;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electromagnetic Compatibility and 19th International Zurich Symposium on Electromagnetic Compatibility, 2008. APEMC 2008. Asia-Pacific Symposium on
  • Conference_Location
    Singapore
  • Print_ISBN
    978-981-08-0629-3
  • Electronic_ISBN
    978-981-08-0629-3
  • Type

    conf

  • DOI
    10.1109/APEMC.2008.4559915
  • Filename
    4559915