DocumentCode
2079929
Title
Partial discharge measurements on the winding bars from a failed machine
Author
Zhou, Y. ; Gardiner, A. ; Mathieson, G. ; Qin, Y.
Author_Institution
Ind. Res. Ltd., Christchurch, New Zealand
fYear
1997
fDate
22-25 Sep 1997
Firstpage
97
Lastpage
100
Abstract
Partial discharge (PD) measurement is an effective tool for the evaluation and monitoring of machine insulation condition. Assessment by PD measurement of the winding bars from a failed electric machine identified the cause of the failure and defined the condition of the insulation. The correlation of PD measurements on the machine prior to failure with the post-failure assessment shows where the PD started, the process and duration of the insulation deterioration, and the signature of the PD signals. The results of the assessment suggest what preventative action should have been taken for the machine. Additionally, this paper introduces new methods of PD measurement. Assessment of insulation by these methods provides an insight to the best choice of insulation in a new or refurbished machine, defines the insulation condition for cost effective preventative maintenance and minimises the cost of repair
Keywords
electric breakdown; electric machines; failure analysis; insulation testing; machine insulation; machine testing; machine windings; partial discharges; PD signal signature; electric machine insulation; insulation breakdown tests; insulation deterioration; insulation evaluation; insulation monitoring; partial discharge measurements; post-failure assessment; preventative maintenance; winding bars;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Insulation Conference, 1997, and Electrical Manufacturing & Coil Winding Conference. Proceedings
Conference_Location
Rosemont, IL
ISSN
0362-2479
Print_ISBN
0-7803-3959-2
Type
conf
DOI
10.1109/EEIC.1997.651007
Filename
651007
Link To Document