DocumentCode
2080642
Title
Quantification of spontaneous and evoked HFO´s in SEEG recording and prospective for pre-surgical diagnostics. Case study
Author
Kalitzin, S. ; Zijlmans, M. ; Petkov, G. ; Velis, D. ; Claus, S. ; Visser, G. ; Koppert, M. ; Lopes da Silva, Fernando
Author_Institution
Found. Epilepsy Inst. of The Netherlands (SEIN), Heemstede, Netherlands
fYear
2012
fDate
Aug. 28 2012-Sept. 1 2012
Firstpage
1024
Lastpage
1027
Abstract
High frequency oscillations (HFO) in stereo electroencephalographic (SEEG) signals have been recently the focus of attention as biomarkers that can have potential predictive power for the spatial location and possibly the timing of the onset of epileptic seizures. In this work we present a case study where we compare two quantitative paradigms for automated detection of biomarkers, one based on spontaneous SEEG recordings of HFOs and the other using activity induced by direct electrical stimulation (relative Phase Clustering Index algorithm). We compare the performance of these automated methods with manually detected HFO ripples by a trained EEG analyst and explore their potential diagnostic relevance. Intracranial recordings from patients undergoing pre-surgical evaluation are processed with a combination of morphological filtering and the analysis of the auto-correlation function. The results were compared to those obtained by visual inspection and to results from an active paradigm involving stimulation with 20 Hz trains of biphasic pulses. The quantity of HFOs, estimated automatically, or “rippleness”, was found to correspond to the findings of a trained EEG analyst. The relative phase clustering index (rPCI) obtained using periodic stimulation appeared to be associated with the closeness to the seizure onset zone (SOZ) detected from ictal epochs. The HFO estimates were also indicative for the SOZ but with less specificity.
Keywords
bioelectric potentials; electroencephalography; medical disorders; medical signal processing; oscillations; patient diagnosis; surgery; SEEG recordings; autocorrelation function; automated biomarker detection; direct electrical stimulation; epileptic seizures; evoked high frequency oscillations; ictal epochs; intracranial recordings; morphological filtering; presurgical diagnostics; relative phase clustering index algorithm; spatial location; spontaneous high frequency oscillations; stereo electroencephalographic signals; visual inspection; Electroencephalography; Epilepsy; Hafnium oxide; Indexes; Oscillators; Visualization; Electroencephalography; Female; Humans; Male; Preoperative Care; Sensitivity and Specificity; Signal Processing, Computer-Assisted;
fLanguage
English
Publisher
ieee
Conference_Titel
Engineering in Medicine and Biology Society (EMBC), 2012 Annual International Conference of the IEEE
Conference_Location
San Diego, CA
ISSN
1557-170X
Print_ISBN
978-1-4244-4119-8
Electronic_ISBN
1557-170X
Type
conf
DOI
10.1109/EMBC.2012.6346108
Filename
6346108
Link To Document