• DocumentCode
    2080642
  • Title

    Quantification of spontaneous and evoked HFO´s in SEEG recording and prospective for pre-surgical diagnostics. Case study

  • Author

    Kalitzin, S. ; Zijlmans, M. ; Petkov, G. ; Velis, D. ; Claus, S. ; Visser, G. ; Koppert, M. ; Lopes da Silva, Fernando

  • Author_Institution
    Found. Epilepsy Inst. of The Netherlands (SEIN), Heemstede, Netherlands
  • fYear
    2012
  • fDate
    Aug. 28 2012-Sept. 1 2012
  • Firstpage
    1024
  • Lastpage
    1027
  • Abstract
    High frequency oscillations (HFO) in stereo electroencephalographic (SEEG) signals have been recently the focus of attention as biomarkers that can have potential predictive power for the spatial location and possibly the timing of the onset of epileptic seizures. In this work we present a case study where we compare two quantitative paradigms for automated detection of biomarkers, one based on spontaneous SEEG recordings of HFOs and the other using activity induced by direct electrical stimulation (relative Phase Clustering Index algorithm). We compare the performance of these automated methods with manually detected HFO ripples by a trained EEG analyst and explore their potential diagnostic relevance. Intracranial recordings from patients undergoing pre-surgical evaluation are processed with a combination of morphological filtering and the analysis of the auto-correlation function. The results were compared to those obtained by visual inspection and to results from an active paradigm involving stimulation with 20 Hz trains of biphasic pulses. The quantity of HFOs, estimated automatically, or “rippleness”, was found to correspond to the findings of a trained EEG analyst. The relative phase clustering index (rPCI) obtained using periodic stimulation appeared to be associated with the closeness to the seizure onset zone (SOZ) detected from ictal epochs. The HFO estimates were also indicative for the SOZ but with less specificity.
  • Keywords
    bioelectric potentials; electroencephalography; medical disorders; medical signal processing; oscillations; patient diagnosis; surgery; SEEG recordings; autocorrelation function; automated biomarker detection; direct electrical stimulation; epileptic seizures; evoked high frequency oscillations; ictal epochs; intracranial recordings; morphological filtering; presurgical diagnostics; relative phase clustering index algorithm; spatial location; spontaneous high frequency oscillations; stereo electroencephalographic signals; visual inspection; Electroencephalography; Epilepsy; Hafnium oxide; Indexes; Oscillators; Visualization; Electroencephalography; Female; Humans; Male; Preoperative Care; Sensitivity and Specificity; Signal Processing, Computer-Assisted;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society (EMBC), 2012 Annual International Conference of the IEEE
  • Conference_Location
    San Diego, CA
  • ISSN
    1557-170X
  • Print_ISBN
    978-1-4244-4119-8
  • Electronic_ISBN
    1557-170X
  • Type

    conf

  • DOI
    10.1109/EMBC.2012.6346108
  • Filename
    6346108