  • Title

    Evaluation of shielding effectiveness on system level by electromagnetic topology based modeling

  • Author

    Monje, C. Alonso ; Helmers, S. ; Díez, E. Galván

  • Author_Institution
    Center for Quality Eng., Siemens AG, Germany
  • fYear
    2005
  • fDate
    21-24 June 2005
  • Firstpage
    61
  • Lastpage
    64
  • Abstract
    The confidence in shielding effectiveness (SE) measurements on enclosures according to IEC TS 61587-3 is evaluated. A methodical analysis using an electromagnetic topology (EMT) based model is carried out to find the electromagnetic (EM) critical aspects. The EMT model represents the interaction between base and auxiliary components which are necessary for testing. As shown in examples, each local coupling effect can be investigated by means of an appropriate, numerical or experimental method. It is displayed how the EMT facilitates the translation of local estimations into the global SE test result.
  • Keywords
    IEC standards; computational electromagnetics; electromagnetic coupling; electromagnetic shielding; EMT model; IEC TS 61587-3 evaluation; SE measurement; auxiliary component; electromagnetic topology; local coupling effect; shielding effectiveness test; Antenna measurements; Attenuation measurement; Electromagnetic compatibility; Electromagnetic measurements; Electromagnetic modeling; Electromagnetic shielding; Electronic equipment testing; IEC standards; Magnetic field measurement; Topology;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electromagnetic Compatibility and Electromagnetic Ecology, 2005. IEEE 6th International Symposium on
  • Print_ISBN
    0-7803-9374-0
  • Type

    conf

  • DOI
    10.1109/EMCECO.2005.1513063
  • Filename
    1513063