DocumentCode
2082708
Title
Evaluation of shielding effectiveness on system level by electromagnetic topology based modeling
Author
Monje, C. Alonso ; Helmers, S. ; Díez, E. Galván
Author_Institution
Center for Quality Eng., Siemens AG, Germany
fYear
2005
fDate
21-24 June 2005
Firstpage
61
Lastpage
64
Abstract
The confidence in shielding effectiveness (SE) measurements on enclosures according to IEC TS 61587-3 is evaluated. A methodical analysis using an electromagnetic topology (EMT) based model is carried out to find the electromagnetic (EM) critical aspects. The EMT model represents the interaction between base and auxiliary components which are necessary for testing. As shown in examples, each local coupling effect can be investigated by means of an appropriate, numerical or experimental method. It is displayed how the EMT facilitates the translation of local estimations into the global SE test result.
Keywords
IEC standards; computational electromagnetics; electromagnetic coupling; electromagnetic shielding; EMT model; IEC TS 61587-3 evaluation; SE measurement; auxiliary component; electromagnetic topology; local coupling effect; shielding effectiveness test; Antenna measurements; Attenuation measurement; Electromagnetic compatibility; Electromagnetic measurements; Electromagnetic modeling; Electromagnetic shielding; Electronic equipment testing; IEC standards; Magnetic field measurement; Topology;
fLanguage
English
Publisher
ieee
Conference_Titel
Electromagnetic Compatibility and Electromagnetic Ecology, 2005. IEEE 6th International Symposium on
Print_ISBN
0-7803-9374-0
Type
conf
DOI
10.1109/EMCECO.2005.1513063
Filename
1513063
Link To Document