DocumentCode
2087925
Title
A review of non-contact, low-cost physiological information measurement based on photoplethysmographic imaging
Author
He Liu ; Yadong Wang ; Lei Wang
Author_Institution
Harbin Inst. of Technol., Harbin, China
fYear
2012
fDate
Aug. 28 2012-Sept. 1 2012
Firstpage
2088
Lastpage
2091
Abstract
In recent decades, there has been increasing interest in low-cost, non-contact and pervasive methods for measuring physiological information, such as heart rate (HR), respiratory rate, heart rate variability (HRV) and oxyhemoglobin saturation. The conventional methods including wet adhesive Ag/AgCl electrodes for HR and HRV, the capnograph device for respiratory status and pulse oximetry for oxyhemoglobin saturation provide excellent signals but are expensive, troublesome and inconvenient. A method to monitor physiological information based on photoplethysmographic imaging offers a new means for health monitoring. Blood volume can be indirectly assessed in terms of blood velocity, blood flow rate and blood pressure, which, in turn, can reflect changes in physiological parameters. Changes in blood volume can be determined from the spectra of light reflected from or transmitted through body tissues. Images of an area of the skin surface are consecutively captured with the color camera of a computer or smartphone and, by processing and analyzing the light signals, physiological information such as HR, respiratory rate, HRV and oxyhemoglobin saturation can be acquired. In this paper, we review the latest developments in using photoplethysmographic imaging for non-contact health monitoring and discuss the challenges and future directions for this field.
Keywords
biomedical electrodes; blood flow measurement; blood pressure measurement; cameras; cardiology; medical image processing; oximetry; photoplethysmography; skin; smart phones; velocity measurement; volume measurement; blood flow rate; blood pressure; blood velocity; blood volume; body tissues; capnograph device; computer color camera; conventional methods; health monitoring; heart rate variability; light reflection; light signals; low-cost physiological information measurement; noncontact physiological information measurement; oxyhemoglobin saturation; photoplethysmographic imaging; pulse oximetry; respiratory rate; skin surface area; smartphone color camera; wet adhesive electrodes; Biomedical monitoring; Blood; Cameras; Heart rate variability; Monitoring; Equipment Design; Equipment Failure Analysis; Humans; Monitoring, Ambulatory; Photoplethysmography; Technology Assessment, Biomedical; Tomography;
fLanguage
English
Publisher
ieee
Conference_Titel
Engineering in Medicine and Biology Society (EMBC), 2012 Annual International Conference of the IEEE
Conference_Location
San Diego, CA
ISSN
1557-170X
Print_ISBN
978-1-4244-4119-8
Electronic_ISBN
1557-170X
Type
conf
DOI
10.1109/EMBC.2012.6346371
Filename
6346371
Link To Document