• DocumentCode
    2098076
  • Title

    A multi-frequency ultrasonic flowmeter applicable to liquid with gas bubbles

  • Author

    Shunjie, Fan ; Yue, Zhuo

  • Author_Institution
    Corp. Technol., Siemens Ltd., China, Beijing, China
  • fYear
    2011
  • fDate
    10-12 May 2011
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    Two-phase flow measurement is a challenging task for ultrasonic flowmeters. This paper introduces a more stable and robust ultrasonic flowmeter technology, which can better cope with liquid flow with enriched gas bubbles. The flowmeter uses broadband ultrasonic transducers and multi-frequency digital signal processing to enhance the signal to noise ratio under gas bubble interference. The same flowmeter can thus measure both dirty and clean flows, widening its application area. An experimental flow system is set up to test the new technology with a benchmark flowmeter.
  • Keywords
    bubbles; flow; flow measurement; flowmeters; signal processing; two-phase flow; ultrasonic transducers; broadband ultrasonic transducer; gas bubble; liquid flow; multifrequency digital signal processing; multifrequency ultrasonic flowmeter; two-phase flow measurement; Acoustics; Benchmark testing; Fluid flow measurement; Interference; Signal to noise ratio; Ultrasonic imaging; Ultrasonic variables measurement; broadband transducer; digital signal processing; gas bubble; two-phase flow; ultrasonic flowmeter;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Instrumentation and Measurement Technology Conference (I2MTC), 2011 IEEE
  • Conference_Location
    Binjiang
  • ISSN
    1091-5281
  • Print_ISBN
    978-1-4244-7933-7
  • Type

    conf

  • DOI
    10.1109/IMTC.2011.5944174
  • Filename
    5944174