DocumentCode
2098076
Title
A multi-frequency ultrasonic flowmeter applicable to liquid with gas bubbles
Author
Shunjie, Fan ; Yue, Zhuo
Author_Institution
Corp. Technol., Siemens Ltd., China, Beijing, China
fYear
2011
fDate
10-12 May 2011
Firstpage
1
Lastpage
4
Abstract
Two-phase flow measurement is a challenging task for ultrasonic flowmeters. This paper introduces a more stable and robust ultrasonic flowmeter technology, which can better cope with liquid flow with enriched gas bubbles. The flowmeter uses broadband ultrasonic transducers and multi-frequency digital signal processing to enhance the signal to noise ratio under gas bubble interference. The same flowmeter can thus measure both dirty and clean flows, widening its application area. An experimental flow system is set up to test the new technology with a benchmark flowmeter.
Keywords
bubbles; flow; flow measurement; flowmeters; signal processing; two-phase flow; ultrasonic transducers; broadband ultrasonic transducer; gas bubble; liquid flow; multifrequency digital signal processing; multifrequency ultrasonic flowmeter; two-phase flow measurement; Acoustics; Benchmark testing; Fluid flow measurement; Interference; Signal to noise ratio; Ultrasonic imaging; Ultrasonic variables measurement; broadband transducer; digital signal processing; gas bubble; two-phase flow; ultrasonic flowmeter;