DocumentCode
2098492
Title
Analysis of magnetic field measurement results for the AGS booster magnets
Author
Bleser, E. ; Thern, R.
Author_Institution
Brookhaven Nat. Lab., Upton, NY, USA
fYear
1991
fDate
6-9 May 1991
Firstpage
45
Abstract
Magnetic field measurements have been made on nearly 200 conventional magnets that have been installed in the AGS (Alternating Gradient Synchrotron) booster and its associated transfer lines. The measurement were intended to monitor the quality of the magnets being produced and to check the performance of each magnet before installation. The magnetic measurements efforts led to certain improvements in the manufacturing process, which subsequently produced very good, very uniform magnets. The integrated dipole fields of the 36 booster dipoles are uniform to 1.5 parts in ten thousand. The magnetic measurements indicate that the quadrupoles were manufactured to an accuracy of 3/10000 inch.<>
Keywords
beam handling equipment; electromagnets; magnetic field measurement; proton accelerators; synchrotrons; AGS; Alternating Gradient Synchrotron; booster magnets; dipole fields; magnetic field measurement; manufacturing process; quality; Coils; Laboratories; Magnetic analysis; Magnetic field measurement; Magnetic variables measurement; Magnets; Manufacturing processes; Measurement standards; Monitoring; Protons;
fLanguage
English
Publisher
ieee
Conference_Titel
Particle Accelerator Conference, 1991. Accelerator Science and Technology., Conference Record of the 1991 IEEE
Conference_Location
San Francisco, CA, USA
Print_ISBN
0-7803-0135-8
Type
conf
DOI
10.1109/PAC.1991.164199
Filename
164199
Link To Document