    Reduction of influence of decrease in SNR of ultrasonic pulse during cardiac cycle in measurement of small change in thickness of arterial wall

  • Author

    Hasegawa, Hideyuki ; Kanai, Hiroshi ; Hoshimiya, Nozomu ; Koiwa, Yoshiro

  • Author_Institution
    Graduate Sch. of Eng., Tohoku Univ., Sendai, Japan
  • Volume
    2
  • fYear
    1999
  • fDate
    1999
  • Firstpage
    1337
  • Abstract
    We have previously proposed a method for measuring the small change in thickness of the arterial wall during the cardiac cycle, which cannot be measured from conventional B-mode or M-mode images because of its small amplitude of less than 100 micrometer. However, in spite of its great usefulness for in vivo assessment of the local elasticity of the arterial wall, there are cases where successful measurements based on only two consecutive echo signals fail because of low signal-to-noise ratio (SNR) during the cardiac cycle. To realize the proposed method in practical use, this problem must be overcome. In this paper, we propose a method that is more robust in the presence of noise. In this method, more than two echo signals are employed in estimation of their phase shift for reducing the influence of low SNR. Simulation experiments provide the optimal value of the estimation period (the number of echo signals) for each SNR. By evaluating the SNR of in vitro experimental data, the optimal estimation period is determined. In in vivo experiment, by using the optimal estimation period of 20 ms, the change in thickness can be measured with good reproducibility even in the case of low SNR of 28 dB
  • Keywords
    biomechanics; biomedical measurement; biomedical ultrasonics; blood vessels; cardiovascular system; elasticity; SNR decrease influence; arterial wall thickness; atherosclerosis; cardiac cycle; common carotid artery; echo signals; in vitro data; in vivo assessment; local elasticity; myocardial infarction; optimal value; phase shift; small thickness change measurement; ultrasonic pulse; Arteries; Elasticity; In vitro; In vivo; Noise robustness; Phase estimation; Reproducibility of results; Signal to noise ratio; Thickness measurement; Ultrasonic variables measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Ultrasonics Symposium, 1999. Proceedings. 1999 IEEE
  • Conference_Location
    Caesars Tahoe, NV
  • ISSN
    1051-0117
  • Print_ISBN
    0-7803-5722-1
  • Type

    conf

  • DOI
    10.1109/ULTSYM.1999.849244
  • Filename
    849244