• DocumentCode
    2103712
  • Title

    Multipactor testing of multiplexer and waveguide components exposed to multiple carrier loading

  • Author

    Geissler, K.H. ; Wolk, D.

  • Author_Institution
    ANT Nachrichtentechnik GmbH, D- 71522 Backnang
  • Volume
    1
  • fYear
    1995
  • fDate
    4-4 Sept. 1995
  • Firstpage
    194
  • Lastpage
    198
  • Abstract
    Measurements of multipaction thresholds obtained with one to 10 carrier signals are reported. Filters of the corrugated type served as test samples. The experimental set-up required for multicarrier tests is described. When n carriers are superimposed, phase adjustment of all signals is essential for n ¿ 3. Wihout phase adjustment the n2P maxima may never occur during testing. The peaks will only occur at constant repetition rate when the test frequencies are separated by multiples of the smallest separation. The ¿ cycle mode appears to be the preferred multipaction mode even in larger gaps.
  • Keywords
    Communication industry; Discharges; Electron emission; Multiplexing; Power harmonic filters; RF signals; Radio frequency; Resonance; Testing; Waveguide components;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Microwave Conference, 1995. 25th European
  • Conference_Location
    Bologna, Italy
  • Type

    conf

  • DOI
    10.1109/EUMA.1995.336945
  • Filename
    4137158