DocumentCode
2103712
Title
Multipactor testing of multiplexer and waveguide components exposed to multiple carrier loading
Author
Geissler, K.H. ; Wolk, D.
Author_Institution
ANT Nachrichtentechnik GmbH, D- 71522 Backnang
Volume
1
fYear
1995
fDate
4-4 Sept. 1995
Firstpage
194
Lastpage
198
Abstract
Measurements of multipaction thresholds obtained with one to 10 carrier signals are reported. Filters of the corrugated type served as test samples. The experimental set-up required for multicarrier tests is described. When n carriers are superimposed, phase adjustment of all signals is essential for n ¿ 3. Wihout phase adjustment the n2P maxima may never occur during testing. The peaks will only occur at constant repetition rate when the test frequencies are separated by multiples of the smallest separation. The ¿ cycle mode appears to be the preferred multipaction mode even in larger gaps.
Keywords
Communication industry; Discharges; Electron emission; Multiplexing; Power harmonic filters; RF signals; Radio frequency; Resonance; Testing; Waveguide components;
fLanguage
English
Publisher
ieee
Conference_Titel
Microwave Conference, 1995. 25th European
Conference_Location
Bologna, Italy
Type
conf
DOI
10.1109/EUMA.1995.336945
Filename
4137158
Link To Document