    A 1.5 mm × 3 mm CMOS chip with sensors for monitoring on-chip cell cultures has been designed. The chip is designed in a 0.5 μm CMOS process which has 3 metal layers and 2 poly layers and is a 5 volt process. The chip contains ion sensitive field effect transistors (ISFETs), as well as ISFETs with read-out circuitry, for monitoring the pH of solutions placed on top of the chip. Interdigitated electrode structures (IDESs) are made using the top metal of the process to be used for sensing cellular attachment and proliferation via impendence. IDES read-out circuits and IDES test structures are included. The chip also contains test amplifiers, bandgap reference test structures, and connections for post-processing. We designed the chip to accommodate packaging into an environment where it will be directly exposed to a cell culture environment. Specifically we designed the chip to have the incorporated sensors near the center of the chip allowing for connections made around the edge of the chip to be sealed off using an epoxy or similar material to prevent shorting. Preliminary electrical characterization results for our amplifier indicate a gain of 48 dB, a bandwidth of 1.65 kHz, and a common mode rejection ratio (CMRR) of 72 dB. We also present a packaging technique using a flexible pcb substrate.
  • Keywords
    CMOS integrated circuits; bioMEMS; bioelectric phenomena; biological techniques; biosensors; cellular biophysics; ion sensitive field effect transistors; microfluidics; operational amplifiers; pH; packaging; CMOS biosensor system; IDES test structures; ISFET; bandgap reference test structures; bandwidth 1.65 kHz; cell culture environment; common mode rejection ratio; flexible pcb substrate; gain 48 dB; gain 72 dB; incorporated sensors; interdigitated electrode structures; ion sensitive field effect transistors; metal layers; microfluidic packaging; on-chip cell culture; pH solutions; packaging technique; preliminary electrical characterization; read-out circuitry; sensing cellular attachment; sensing cellular proliferation; test amplifiers; CMOS integrated circuits; Capacitance; Capacitive sensors; Metals; Monitoring; Packaging; Animals; Biosensing Techniques; Cell Culture Techniques; Cells, Cultured; Conductometry; Equipment Design; Equipment Failure Analysis; Humans; Microfluidic Analytical Techniques; Reproducibility of Results; Sensitivity and Specificity; Transistors, Electronic; User-Computer Interface;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society (EMBC), 2012 Annual International Conference of the IEEE
  • Conference_Location
    San Diego, CA
  • ISSN
    1557-170X
  • Print_ISBN
    978-1-4244-4119-8
  • Electronic_ISBN
    1557-170X
  • Type

    conf

  • DOI
    10.1109/EMBC.2012.6347113
  • Filename
    6347113