Abstract
APS and PWEC have long been exploiting both preventive and predictive maintenance technologies as a means of increasing generation reliability. This paper documents the details of the successful application of one such technology, which facilitated operating both steam turbine generators (STGs) at Redhawk power plant through the summer 2003 peak as well as monitoring the performance of subsequent modifications.
Keywords
monitoring; power generation reliability; steam turbines; turbogenerators; Arizona public service company; Pinnacle west energy corporation; Redhawk power plant; generation reliability; generator end turn vibration monitoring; steam turbine generators; Assembly; Combustion; Instruments; Manufacturing; Monitoring; Packaging machines; Power generation; Power industry; Predictive maintenance; Turbines;