• DocumentCode
    2107468
  • Title

    Modified Log-LMS adaptive filter with low signal distortion for biomedical applications

  • Author

    Yuzhong Jiao ; Cheung, Rex Y. P. ; Mok, Mark P. C.

  • Author_Institution
    Hong Kong Appl. Sci. & Technol. Res. Inst. (ASTRI), Hong Kong, China
  • fYear
    2012
  • fDate
    Aug. 28 2012-Sept. 1 2012
  • Firstpage
    5210
  • Lastpage
    5213
  • Abstract
    Life signals from human body, e.g. heartbeat or electrocardiography (ECG), are usually weak and susceptible to external noise and interference. Adaptive filter is a good tool to reduce the influence of ambient noise/interference on the life signals. Least mean squares (LMS) algorithm, as one of most popular adaptive algorithms for active noise cancellation (ANC) by adaptive filtering, has the advantage of easy implementation. In order to further decrease the complexity of LMS algorithm based adaptive filter, a Log-LMS algorithm was proposed, which quantized signals by the function of log2. The algorithm can replace multipliers by simple shifting. However, both LMS algorithm and Log-LMS algorithm have the disadvantage of serious signal distortion in biomedical applications. In this paper, a modified Log-LMS algorithm is presented, which divides the convergence process into two different stages, and utilizes different quantization method in each stage. Two scenarios of biomedical applications are used for analysis, 1) using stethoscope in emergence medical helicopter and 2) measuring ECG under power line interference. The simulated results show that the modified algorithm can achieve fast convergence and low signal distortion in processing periodic life signals.
  • Keywords
    active noise control; adaptive filters; convergence; distortion; electrocardiography; emergency services; interference suppression; least mean squares methods; medical signal processing; quantisation (signal); ANC; ECG measurement; active noise cancellation; adaptive algorithm; adaptive filter; biomedical application; convergence process; emergence medical helicopter; least mean square algorithm; log-LMS algorithm; periodic life signal; power line interference; signal distortion; signal quantization method; stethoscope; Adaptive filters; Convergence; Distortion; Electrocardiography; Interference; Noise; Stethoscope; Algorithms; Artifacts; Diagnosis, Computer-Assisted; Monitoring, Physiologic; Reproducibility of Results; Sensitivity and Specificity; Signal Processing, Computer-Assisted; Signal-To-Noise Ratio;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society (EMBC), 2012 Annual International Conference of the IEEE
  • Conference_Location
    San Diego, CA
  • ISSN
    1557-170X
  • Print_ISBN
    978-1-4244-4119-8
  • Electronic_ISBN
    1557-170X
  • Type

    conf

  • DOI
    10.1109/EMBC.2012.6347168
  • Filename
    6347168