• DocumentCode
    2110247
  • Title

    Comparative limestone and seawater method in Desulfurization system

  • Author

    Lee, Jia-Twu ; Chen, Min-Chu

  • fYear
    2012
  • fDate
    21-23 April 2012
  • Firstpage
    2459
  • Lastpage
    2463
  • Abstract
    The Power plant flue gas of coal-fired units are in addition to the sulfur removal system (Flue Gas Desulfurization, referred to as FGD) wet limestone/gypsum, in need of using a lot of fresh water and limestone, which can be the formation of another waste problem. The sea water flue gas desulphurization system, the sulfur removal efficiency can reach 90% or more. Large coal-fired units almost have sea water flue gas desulphurization system, and Formosa Plastics Mailiao power plant in Taiwan has also pioneered the use of the international community. The aim of the study are to compare the advantages and disadvantages of limestone and seawater method. The advantages and disadvantages of the sulfur remove system operators are expected to explore the practical operation of the seawater FGD.
  • Keywords
    flue gas desulphurisation; seawater; steam power stations; FGD; Taiwan; coal-fired units; formosa plastics mailiao power plant; gypsum; limestone method; power plant flue gas; sea water flue gas desulfurization system; seawater method; sulfur removal system; wet limestone; Coal; Communities; Desalination; Manuals; Power generation; Reverse osmosis; Water pollution; FGD; SO2; coal; sea water;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Consumer Electronics, Communications and Networks (CECNet), 2012 2nd International Conference on
  • Conference_Location
    Yichang
  • Print_ISBN
    978-1-4577-1414-6
  • Type

    conf

  • DOI
    10.1109/CECNet.2012.6201385
  • Filename
    6201385