• DocumentCode
    2111194
  • Title

    Data filtering in the readout of the CMS Electromagnetic Calorimeter

  • Author

    Almeida, N. ; Silva, P. ; Da Silva, J.C. ; Husejko, M. ; Jain, A. ; Musella, P. ; Mendes, A. ; Gallinaro, M. ; Varela, J. ; Faure, J.-L. ; Gras, P. ; Mandjavidze, I. ; Busson, P. ; Paganini, P.

  • Author_Institution
    Lab. de Instrum. e Fisica Exp. de Particulas, Lisbon
  • fYear
    2007
  • fDate
    April 29 2007-May 4 2007
  • Firstpage
    1
  • Lastpage
    5
  • Abstract
    For an efficient data taking, the electromagnetic calorimeter (ECAL) data of the CMS experiment must be limited to 10% of the full event size (1 MB). Other requirements limit the average data size to 2 kB per data acquisition link. These conditions imply a reduction factor of close to twenty on the data collected. The data filtering in the readout of the ECAL detector is discussed. Test beam data are used to study the digital filtering applied in the readout channels and a full detector simulation allows to estimate the energy thresholds to achieve the desired data suppression factor.
  • Keywords
    data acquisition; particle calorimetry; CMS Electromagnetic Calorimeter readout; Compact Muon Solenoid; ECAL; LHC; Large Hadron Collider; data acquisition; data filtering; digital filtering; readout channels; trigger systems; Collision mitigation; Data acquisition; Detectors; Digital filters; Electron beams; Filtering algorithms; Large Hadron Collider; Photonic crystals; Strontium; Testing; CMS; Data Acquisition; Data Filtering; LHC; Selective Readout; Trigger System; Trigger Systems;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Real-Time Conference, 2007 15th IEEE-NPSS
  • Conference_Location
    Batavia, IL
  • Print_ISBN
    978-1-4244-0866-5
  • Electronic_ISBN
    978-1-4244-0867-2
  • Type

    conf

  • DOI
    10.1109/RTC.2007.4382838
  • Filename
    4382838