• DocumentCode
    2131131
  • Title

    High-accuracy voltage and current transmission by a four-coaxial cable

  • Author

    Cabiati, F. ; D´Elia, V.

  • Author_Institution
    Ist. Elettrotecnico Nazionale Galileo Ferraris, Torino, Italy
  • fYear
    2000
  • fDate
    14-19 May 2000
  • Firstpage
    435
  • Lastpage
    436
  • Abstract
    The features of a four-coaxial line are recalled and an original compensation technique that reduces the voltage or current transmission error to below 10/sup -10/ at low frequency is presented. Active circuits suitable for the reproduction of EMFs or impressed currents of real generators within a high-precision measuring system even in loaded condition are shown.
  • Keywords
    coaxial cables; measurement errors; measurement systems; multiconductor transmission lines; EMFs; active circuits; compensation technique; current transmission error; four-coaxial cable; high-precision measuring syste; impressed currents; loaded condition; voltage transmission error; Active circuits; Admittance; Coaxial cables; Conductors; Current measurement; Frequency; Inductance; Roentgenium; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements Digest, 2000 Conference on
  • Conference_Location
    Sydney, NSW, Australia
  • Print_ISBN
    0-7803-5744-2
  • Type

    conf

  • DOI
    10.1109/CPEM.2000.851062
  • Filename
    851062