DocumentCode
2134555
Title
Evaluation of solid-state temperature control of silicon packages
Author
Dirner, John P. ; Lopez, Celienid ; Prstic, Suzana ; Cass, Steve
Author_Institution
Intel Corp., Chandler, AZ
fYear
2006
fDate
May 30 2006-June 2 2006
Lastpage
457
Abstract
A metrology which can isothermally control die and package temperature is an essential tool for calibrating temperature sensors. Ovens or isothermal baths are commonly used for temperature calibration, but these pieces of equipment have long throughput times. A calibration method with a shorter TPT has been developed, in which thermoelectric modules are used to control package temperature for temperature sensor calibration. This could enable calibration of all packages individually, and improve the accuracy of thermal testing. A setup was constructed to evaluate the temperature uniformity attained by heating a package with thermoelectric modules and the feasibility of calibration using this method. A major success factor of this setup was its ability to create uniform temperature at the silicon die, and experimental results verified die temperature uniformity was within 0.2 degC for two die sizes. Calibration results from the solid-state metrology matched those obtained using an isothermal liquid bath
Keywords
calibration; ovens; silicon; temperature control; temperature sensors; thermal management (packaging); thermoelectric devices; 0.2 C; Si; die temperature uniformity; isothermal baths; isothermal liquid bath; package temperature; silicon die; silicon packages; solid-state metrology; solid-state temperature control; temperature calibration; temperature sensor calibration; thermal testing; thermoelectric modules; Calibration; Isothermal processes; Metrology; Ovens; Packaging machines; Silicon; Solid state circuits; Temperature control; Temperature sensors; Thermoelectricity;
fLanguage
English
Publisher
ieee
Conference_Titel
Thermal and Thermomechanical Phenomena in Electronics Systems, 2006. ITHERM '06. The Tenth Intersociety Conference on
Conference_Location
San Diego, CA
ISSN
1087-9870
Print_ISBN
0-7803-9524-7
Type
conf
DOI
10.1109/ITHERM.2006.1645378
Filename
1645378
Link To Document