  • Title

    Evaluation of longitudinal conversion loss (LCL) for indoor AC mains line

  • Author

    Rashid, A. K M Mahbub Ar ; Kuwabara, Nobuo ; Maki, Masahiro ; Akiyama, Yoshiharu ; Yamane, Hiroshi

  • Author_Institution
    Fac. of Eng., Kyushu Inst. of Technol., Fukuoka, Japan
  • Volume
    2
  • fYear
    2003
  • fDate
    18-22 Aug. 2003
  • Firstpage
    771
  • Abstract
    Influence to electromagnetic environment has been studied for power line communication (PLC). Longitudinal conversion loss (LCL) and input impedance are important parameters to evaluate the influence. Indoor AC mains line is modeled considering with typical conditions of Japanese house. The modeled line and electric equipment are presented with 4-port F-matrixes. The parameters of 4-port F-matrix are determined from calculation and measurement. Using this model, the input impedance and the LCL are calculated. The analysis model is examined by a simple network, and the results show that the calculation values almost agree with the measured values. The input impedance and the LCL are investigated for actual AC mains line, and the measured results almost agree with the calculated value.
  • Keywords
    carrier transmission on power lines; transmission line matrix methods; transmission lines; 4-port F-matrix; LCL; PLC; common mode impedance; indoor AC mains line; input impedance; longitudinal conversion loss; power line communication; Argon; Cables; Home appliances; Impedance measurement; Plugs; Power line communications; Programmable control; Sockets; Topology; Transmission line measurements;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electromagnetic Compatibility, 2003 IEEE International Symposium on
  • Print_ISBN
    0-7803-7835-0
  • Type

    conf

  • DOI
    10.1109/ISEMC.2003.1236705
  • Filename
    1236705