• DocumentCode
    2146041
  • Title

    Radiated immunity testing of a device with an external wire: repeatability of reverberation chamber results and correlation with anechoic chamber results

  • Author

    Musso, L. ; Canavero, F. ; Demoulin, B. ; Berat, V.

  • Author_Institution
    Departement of Electron., Politecnico di Torino, Turin, Italy
  • Volume
    2
  • fYear
    2003
  • fDate
    18-22 Aug. 2003
  • Firstpage
    828
  • Abstract
    We present the experimental radiated immunity results of an electronic device with an external wire obtained in reverberation and anechoic chambers. Repeatability and reproducibility of reverberation chamber measurements are investigated by repeating the test in three reverberation chambers with different characteristics. We show how the current state of the art allows a statistical control of RC measurement repeatability within an industrial installation, and that a statistical correlation with AC results frequency by frequency is possible in particular cases relevant to automotive applications.
  • Keywords
    anechoic chambers (electromagnetic); electron device testing; immunity testing; reverberation chambers; AC results; RC measurement repeatability; anechoic chamber; automotive EMC; electronic device; external wire; mode tuning; radiated immunity testing; reverberation chamber; statistical control; statistical correlation; Anechoic chambers; Current measurement; Frequency measurement; Immunity testing; Industrial control; Particle measurements; Radio control; Reproducibility of results; Reverberation chamber; Wire;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electromagnetic Compatibility, 2003 IEEE International Symposium on
  • Print_ISBN
    0-7803-7835-0
  • Type

    conf

  • DOI
    10.1109/ISEMC.2003.1236715
  • Filename
    1236715