Low cost power failure protection for MLC NAND flash storage systems with PRAM/DRAM hybrid buffer
Author
Guo, Jie ; Yang, Jun ; Zhang, Youtao ; Chen, Yiran
Author_Institution
Department of Electrical and Computer Engineering, University of Pittsburgh, USA
fYear
2013
fDate
18-22 March 2013
Firstpage
859
Lastpage
864
Abstract
In the latest PRAM/DRAM hybrid MLC NAND flash storage systems (NFSS), DRAM is used to temporarily store file system data for system response time reduction. To ensure data integrity, super-capacitors are deployed to supply the backup power for moving the data from DRAM to NAND flash during power failures. However, the capacitance degradation of super-capacitor severely impairs system robustness. In this work, we proposed a low cost power failure protection scheme to reduce the energy consumption of power failure protection and increase the robustness of the NFSS with PRAM/DRAM hybrid buffer. Our scheme enables the adoption of the more reliable regular capacitor to replace the super capacitor as the backup power. The experimental result shows that our scheme can substantially reduce the capacitance budget of power failure protection circuitry by 75.1% with very marginal performance and energy overheads.
Keywords
Bandwidth; Flash memories; Phase change random access memory; Registers; Robustness; Timing;
fLanguage
English
Publisher
ieee
Conference_Titel
Design, Automation & Test in Europe Conference & Exhibition (DATE), 2013
Conference_Location
Grenoble, France
ISSN
1530-1591
Print_ISBN
978-1-4673-5071-6
Type
conf
DOI
10.7873/DATE.2013.181
Filename
6513627
Link To Document