• DocumentCode
    2159035
  • Title

    Diagnosis and cure of a transverse instability in the NSLS VUV ring

  • Author

    Rose, J. ; Biscardi, R. ; Broome, W. ; D´Alsace, R. ; Keane, J. ; Wang, J.M.

  • Author_Institution
    Brookhaven Nat. Lab., Upton, NY, USA
  • fYear
    1991
  • fDate
    6-9 May 1991
  • Firstpage
    1794
  • Abstract
    In the National Synchrotron Light Source (NSLS) Vacuum Ultraviolet (VUV) ring, a beam instability occurred as a function of cavity tuner position, restricting the operating range of the tuner and requiring the cavity to operate at an elevated temperature to compensate. The cavity mode responsible for the instability was diagnosed and subsequently damped with a tuned probe terminated in 50 Omega . The instability was cured, and has not been observed up to the design current of 1-A stored beam.<>
  • Keywords
    electron accelerators; particle beam diagnostics; storage rings; NSLS VUV ring; beam instability; cavity tuner position; tuned probe; Electron beams; Frequency; Impedance; Laboratories; Light sources; Probes; Synchrotrons; Temperature distribution; Tuners; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 1991. Accelerator Science and Technology., Conference Record of the 1991 IEEE
  • Conference_Location
    San Francisco, CA, USA
  • Print_ISBN
    0-7803-0135-8
  • Type

    conf

  • DOI
    10.1109/PAC.1991.164780
  • Filename
    164780