DocumentCode
2190526
Title
The Jefferson Lab high resolution TDC module
Author
Barbosa, F.J. ; Jastrzembski, E. ; Proffitt, J. ; Wilson, J.
Author_Institution
Thomas Jefferson Nat. Accelerator Facility, Newport News, VA, USA
Volume
1
fYear
2002
fDate
10-16 Nov. 2002
Firstpage
135
Abstract
We discuss the design of a high resolution TDC module for use in nuclear physics experiments at Jefferson Lab. Preliminary results on the performance of the prototype module are presented.
Keywords
discriminators; filtering theory; nuclear electronics; readout electronics; timing circuits; trigger circuits; Continuous Electron Beam Accelerator Facility; Jefferson Lab high resolution TDC module; complex filtering; custom integrated circuits; prototype module; trigger; Clocks; Counting circuits; Delay; Electron accelerators; Electron beams; Fastbus; Nuclear physics; Phase frequency detector; Prototypes; Semiconductor device measurement;