• DocumentCode
    2211625
  • Title

    Simultaneous SPECT and CT with an opposed dual head gamma camera system and conventional parallel hole collimators

  • Author

    Kimiaei, S. ; Larsson, S.A.

  • Author_Institution
    Dept. of Hospital Phys., Karolinska Hospital, Stockholm, Sweden
  • Volume
    2
  • fYear
    1995
  • fDate
    21-28 Oct 1995
  • Firstpage
    954
  • Abstract
    All examinations aiming at quantitative assessment of activity concentrations suffer from non-uniform attenuation due to inhomogenous tissue density in various body regions. In such applications, a combined transmission tomography with SPECT has demonstrated great clinical advantages since it allows a pixel by pixel correction for attenuation based on measured data. The authors have developed a method for transmission studies that is applicable to dual head detector systems with conventional parallel-hole collimators. A scanning line-source (Am-241) is mounted close to one camera head with the beam directed towards the other head. Two energy discrimination windows are used for each camera head. The camera-head near to the transmission source registrates SPECT-data in one window and the spill-over of scattered emission photons into the Am-window. The opposed camera registrates SPECT-data in one window and the transmission data from the Am-source in the second one. Post acquisition corrections are made for differences in camera uniformity and the loss of SPECT-data due to shadowing of the field-of-view during the transverse movement of the transmission device (about 5%). The height of the collimated slit source is only 30 mm to allow a close adjustment of both camera heads to the patient
  • Keywords
    computerised tomography; single photon emission computed tomography; Am; activity concentrations; attenuation correction; body regions; camera heads close adjustment; clinical advantages; collimated slit source; conventional parallel hole collimators; energy discrimination windows; field-of-view shadowing; inhomogenous tissue density; medical diagnostic imaging; nonuniform attenuation; nuclear medicine; opposed dual head gamma camera system; pixel by pixel correction; simultaneous SPECT/CT; Attenuation measurement; Body regions; Cameras; Collimators; Computed tomography; Detectors; Electromagnetic scattering; Magnetic heads; Particle scattering; Single photon emission computed tomography;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium and Medical Imaging Conference Record, 1995., 1995 IEEE
  • Conference_Location
    San Francisco, CA
  • Print_ISBN
    0-7803-3180-X
  • Type

    conf

  • DOI
    10.1109/NSSMIC.1995.510425
  • Filename
    510425