DocumentCode
2221320
Title
Electric-field strengths measured near personal transceivers
Author
Adams, John
Author_Institution
Nat. Inst. of Stand. & Technol., Boulder, CO, USA
fYear
1993
fDate
9-13 Aug 1993
Firstpage
42
Lastpage
45
Abstract
Electric-field strengths were measured at a number of points near 5-W personal transceivers. The points were located on cylinders of revolution with radii of 7 and 12 cm around the antenna. The transceivers operated on four authorized frequencies of 40.27, 162.475, 464, and 823 MHz, and radiated powers of 5, 5, 5, and 3 W, respectively. In some cases, these measured values exceeded the exposure limits suggested in ANSI Standards C95.1-1982. They are quite significantly higher at 40 and 162 MHz. What effect this has on humans is not known
Keywords
electric field measurement; electronic equipment testing; test facilities; transceivers; 162.475 MHz; 3 W; 40.27 MHz; 464 MHz; 5 W; 823 MHz; ANSI standard; VHF; antenna; cylinders of revolution; electric field strength measurement; exposure limits; humans; personal transceivers; radiated powers; ANSI standards; Antenna measurements; Electric variables measurement; Frequency; NIST; Power generation; Probes; Reflection; Switches; Transceivers;
fLanguage
English
Publisher
ieee
Conference_Titel
Electromagnetic Compatibility, 1993. Symposium Record., 1993 IEEE International Symposium on
Conference_Location
Dallas, TX
Print_ISBN
0-7803-1304-6
Type
conf
DOI
10.1109/ISEMC.1993.473783
Filename
473783
Link To Document