• DocumentCode
    2222836
  • Title

    Examination of additional rotor-losses in inverter-fed induction machines

  • Author

    Rapp, Holger

  • fYear
    1993
  • fDate
    15-19 Nov 1993
  • Firstpage
    881
  • Abstract
    In the rotor of an inverter-fed induction machine, a considerable power-loss may occur, which is caused by the pulsed output voltages of the inverter. This loss can reach unexpectedly high values and in the worst case it may lead to the destruction of the machine. The major part of that loss is caused by the harmonics of the stator currents, which are compensated by corresponding currents in the rotor´s squirrel cage. Unfortunately, field diffusion effects lead to a very inhomogeneous distribution of current density across the rotor bars. Hence, there will appear high peak values of current density in the rotor bars and, in consequence, a considerable and unexpectedly high power loss. The following paper shows a method for analyzing the distribution of current density across the rotor bars and determining the resulting additional rotor loss, that has to be expected. By this way, the machine itself as well as the inverter and its pulse pattern can be optimized in order to reduce this power-loss
  • Keywords
    Air gaps; Bars; Current density; Induction machines; Magnetic cores; Magnetic flux; Pulse inverters; Stator cores; Stator windings; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Industrial Electronics, Control, and Instrumentation, 1993. Proceedings of the IECON '93., International Conference on
  • Conference_Location
    Maui, HI
  • Print_ISBN
    0-7803-0891-3
  • Type

    conf

  • DOI
    10.1109/IECON.1993.339159
  • Filename
    339159