DocumentCode
2222836
Title
Examination of additional rotor-losses in inverter-fed induction machines
Author
Rapp, Holger
fYear
1993
fDate
15-19 Nov 1993
Firstpage
881
Abstract
In the rotor of an inverter-fed induction machine, a considerable power-loss may occur, which is caused by the pulsed output voltages of the inverter. This loss can reach unexpectedly high values and in the worst case it may lead to the destruction of the machine. The major part of that loss is caused by the harmonics of the stator currents, which are compensated by corresponding currents in the rotor´s squirrel cage. Unfortunately, field diffusion effects lead to a very inhomogeneous distribution of current density across the rotor bars. Hence, there will appear high peak values of current density in the rotor bars and, in consequence, a considerable and unexpectedly high power loss. The following paper shows a method for analyzing the distribution of current density across the rotor bars and determining the resulting additional rotor loss, that has to be expected. By this way, the machine itself as well as the inverter and its pulse pattern can be optimized in order to reduce this power-loss
Keywords
Air gaps; Bars; Current density; Induction machines; Magnetic cores; Magnetic flux; Pulse inverters; Stator cores; Stator windings; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Industrial Electronics, Control, and Instrumentation, 1993. Proceedings of the IECON '93., International Conference on
Conference_Location
Maui, HI
Print_ISBN
0-7803-0891-3
Type
conf
DOI
10.1109/IECON.1993.339159
Filename
339159
Link To Document