• DocumentCode
    2228373
  • Title

    Least-squares fitting procedure for setting RF phase and amplitude in drift-tube-linac tanks

  • Author

    Guy, F.W. ; Wangler, T.P.

  • Author_Institution
    Superconducting Super Collider Lab., Dallas, TX, USA
  • fYear
    1991
  • fDate
    6-9 May 1991
  • Firstpage
    3056
  • Abstract
    A method involving the use of least-squares analysis of relative phase measurements is presented. In this method bunch phases relative to RF power are measured at the input and output of the tank and at a reasonable drive distance downstream (or after the next tank with its RF off). The RF phase and amplitude are varied in a predetermined way; the resulting measured phase shifts are compared by least-squares fitting with their corresponding values from a beam-dynamics code simulation. The absolute calibration errors (assumed constant) of the phase sensors are the quantities which are varied to obtain the best fit. If these calibration errors are known, absolute values of RF phase and amplitude can be determined and the correct values set in the tank.<>
  • Keywords
    calibration; least squares approximations; linear accelerators; RF amplitude; RF phase; RF power; absolute calibration errors; beam-dynamics code simulation; bunch phases; drift-tube-linac tanks; least-squares analysis; relative phase measurements; Application software; Calibration; Drives; Error correction; Laboratories; Linear particle accelerator; Phase measurement; Power measurement; Pulse measurements; Radio frequency;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 1991. Accelerator Science and Technology., Conference Record of the 1991 IEEE
  • Conference_Location
    San Francisco, CA, USA
  • Print_ISBN
    0-7803-0135-8
  • Type

    conf

  • DOI
    10.1109/PAC.1991.165185
  • Filename