• DocumentCode
    2233884
  • Title

    Sphygmochronomat: a package for the non-inferential and inferential chronobiometry of blood pressure monitoring using microcomputers

  • Author

    Cugini, Pietro

  • Author_Institution
    Endocrine Pathophysiol. Dept., Rome Univ., Italy
  • fYear
    1989
  • fDate
    26-27 Jun 1989
  • Firstpage
    244
  • Lastpage
    248
  • Abstract
    A computer comparison of individual blood pressure profiles over time, with reference limits derived from databases obtained from clinically healthy peers, is summarized on special forms, called Sphygmochrons. an integrated system written in BASIC for a fully automated compilation of the Sphygmochron is presented. It is interactive and user-friendly and can accommodate both nonambulatory and ambulatory devices for the noninvasive monitoring of blood pressure. It constitutes an online bedside system for a real-time computation of the Sphygmochron
  • Keywords
    computerised monitoring; haemodynamics; interactive systems; medical computing; microcomputer applications; real-time systems; software packages; BASIC; Sphygmochronomat; automated compilation; blood pressure monitoring; chronobiometry; integrated system; interactive; microcomputers; online bedside system; real-time computation; software package; user-friendly; Biomedical monitoring; Blood pressure; Chronobiology; Circadian rhythm; Computerized monitoring; Endocrine system; Frequency; Measurement standards; Microcomputers; Packaging;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Computer-Based Medical Systems,1989. Proceedings., Second Annual IEEE Symposium on
  • Conference_Location
    Minneapolis, MN
  • Print_ISBN
    0-8186-1960-0
  • Type

    conf

  • DOI
    10.1109/CBMSYS.1989.47384
  • Filename
    47384