• DocumentCode
    2261463
  • Title

    High-precision measurement of radar carrier frequency

  • Author

    Li, Donghai ; Zhao, Yongjun ; Zhang, Tao ; Wang, Zhenxing

  • Author_Institution
    The Inf. Eng. Univ., Henan, China
  • fYear
    2001
  • fDate
    2001
  • Firstpage
    241
  • Lastpage
    243
  • Abstract
    When measuring the radar carrier frequency (RCF) via DFT, the frequency resolution is 1/2N, where N is the length of the DFT sequence. To improve the frequency measurement precision, the length of the DFT sequence must be increased, thus the computation is increased too. This paper is intended to introduce a modified algorithm, experimental results of which indicate that 10 to 100 times more measurement precision can be achieved while keeping computation fixed
  • Keywords
    discrete Fourier transforms; frequency measurement; radar resolution; radar theory; DFT sequence; frequency measurement; frequency resolution; measurement precision; radar carrier frequency; Frequency measurement; Interference; Length measurement; Radar measurements; Reconnaissance; Signal resolution; Time measurement; Zinc; Zirconium;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Radar, 2001 CIE International Conference on, Proceedings
  • Conference_Location
    Beijing
  • Print_ISBN
    0-7803-7000-7
  • Type

    conf

  • DOI
    10.1109/ICR.2001.984664
  • Filename
    984664