DocumentCode
2280242
Title
The serial and parallel self-calibration of DC comparator up to 5kA
Author
Shao, Haiming ; Liang, Bo ; Lin, Feipeng ; Wang, Hao ; Li, Zhibin
Author_Institution
Tianjin Univ., Tianjin
fYear
2008
fDate
8-13 June 2008
Firstpage
538
Lastpage
539
Abstract
The deviation of serial and parallel ratios of direct current (DCC) comparator is investigated. By matching the currents passing the paralleled windings with the same nominal value, the deviation of the ratio of a group paralleled windings to the same group serial windings could be reduced to a negligible level. A suit of DCC with serial and parallel structure was developed to build the traceability of DC current up to 5 kA with uncertainties better than 1 times 10-6.
Keywords
calibration; comparators (circuits); windings; DC comparator self-calibration; parallel winding; Equations; Metrology; Resistors; Uncertainty; Direct Current; Direct Current Comparator (DCC); Direct Current Ratio;
fLanguage
English
Publisher
ieee
Conference_Titel
Precision Electromagnetic Measurements Digest, 2008. CPEM 2008. Conference on
Conference_Location
Broomfield, CO
Print_ISBN
978-1-4244-2399-6
Electronic_ISBN
978-1-4244-2400-9
Type
conf
DOI
10.1109/CPEM.2008.4574891
Filename
4574891
Link To Document