    The serial and parallel self-calibration of DC comparator up to 5kA

  • Author

    Shao, Haiming ; Liang, Bo ; Lin, Feipeng ; Wang, Hao ; Li, Zhibin

  • Author_Institution
    Tianjin Univ., Tianjin
  • fYear
    2008
  • fDate
    8-13 June 2008
  • Firstpage
    538
  • Lastpage
    539
  • Abstract
    The deviation of serial and parallel ratios of direct current (DCC) comparator is investigated. By matching the currents passing the paralleled windings with the same nominal value, the deviation of the ratio of a group paralleled windings to the same group serial windings could be reduced to a negligible level. A suit of DCC with serial and parallel structure was developed to build the traceability of DC current up to 5 kA with uncertainties better than 1 times 10-6.
  • Keywords
    calibration; comparators (circuits); windings; DC comparator self-calibration; parallel winding; Equations; Metrology; Resistors; Uncertainty; Direct Current; Direct Current Comparator (DCC); Direct Current Ratio;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements Digest, 2008. CPEM 2008. Conference on
  • Conference_Location
    Broomfield, CO
  • Print_ISBN
    978-1-4244-2399-6
  • Electronic_ISBN
    978-1-4244-2400-9
  • Type

    conf

  • DOI
    10.1109/CPEM.2008.4574891
  • Filename
    4574891