• DocumentCode
    2280589
  • Title

    Magnetic circuit calculation of non-salient pole synchronous generator based on distributed magnetic circuit method

  • Author

    Guo, Yunjun ; Wang, Dong ; Liu, Dezhi ; Wu, Xinzhen ; Chen, Junquan

  • Author_Institution
    Nat. Key Lab. for Vessel Integrated Power Syst. Technol., Naval Univ. of Eng., Wuhan, China
  • fYear
    2011
  • fDate
    20-23 Aug. 2011
  • Firstpage
    1
  • Lastpage
    6
  • Abstract
    Due to low-accuracy of traditional magnetic circuit method with single magnetic loop and some approximate empirical formulas in the magnetic circuit calculation of non-salient pole synchronous generator, the distributed magnetic circuit method (DMCM) is put forward and adopted. The comparison of the results among traditional magnetic circuit method, DMCM and finite-element method (FEM) shows the validity and high-accuracy of DMCM. Furthermore, DMCM is more suitable for some special rotor configuration with subsidiary slots, ventilation slots or the slots for q-axis windings.
  • Keywords
    approximation theory; finite element analysis; machine windings; magnetic circuits; synchronous generators; DMCM; FEM; approximate empirical formula; distributed magnetic circuit method; finite-element method; magnetic circuit calculation; nonsalient pole synchronous generator; q-axis winding slot; rotor configuration; single magnetic loop; subsidiary slot; ventilation slot; Air gaps; Finite element methods; Magnetic circuits; Magnetic flux; Rotors; Stator windings; Air-gap flux density iterative computations; Distributed magnetic circuit method; Magnetic circuit calculation; Non-salient pole synchronous generator;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Machines and Systems (ICEMS), 2011 International Conference on
  • Conference_Location
    Beijing
  • Print_ISBN
    978-1-4577-1044-5
  • Type

    conf

  • DOI
    10.1109/ICEMS.2011.6073821
  • Filename
    6073821