DocumentCode
2282218
Title
Projecting Zener DC reference performance between calibrations
Author
Hamilton, C.A. ; Tarr, L.W.
Author_Institution
VMetrix, Boulder, CO, USA
fYear
2002
fDate
16-21 June 2002
Firstpage
170
Lastpage
171
Abstract
Two empirical models are proposed to predict Zener reference standard output voltage based on just 1 or 2 calibration points. The models are derived from a study of 87 Zener standards. The results yield up to a 60% reduction in uncertainty relative to the manufacturer´s specification and illustrate the dominance of seasonal effects.
Keywords
Zener diodes; calibration; measurement standards; measurement uncertainty; voltage measurement; Zener DC reference standard; calibration; empirical model; measurement uncertainty; output voltage; seasonal effect; Calibration; History; Laboratories; Manufacturing; Measurement standards; Noise measurement; Predictive models; Testing; Uncertainty; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Precision Electromagnetic Measurements, 2002. Conference Digest 2002 Conference on
Conference_Location
Ottawa, Ontario, Canada
Print_ISBN
0-7803-7242-5
Type
conf
DOI
10.1109/CPEM.2002.1034774
Filename
1034774
Link To Document