DocumentCode
2284782
Title
Thrust origin in EHD lifters
Author
Zhao, Lin ; Liaw, Teck-Meng
Author_Institution
Gannon Univ., Erie, PA, USA
fYear
2011
fDate
9-13 Oct. 2011
Firstpage
1
Lastpage
5
Abstract
This paper1 presents the results of the analytical and experimental studies of thrust origin in electrohydrodynamic lifters. It was found that the thrust is the reactive force to the force driving the EHD flow when the electric corona discharge takes place. The results of the experiments confirmed that the thrust is mainly applied on the ground electrode and the net force on the corona wire is negative. The configuration of the lifter affects the thrust but simply increasing the number of corona wires won´t increase the thrust.
Keywords
corona; electrohydrodynamics; plasma devices; plasma transport processes; EHD flow analysis; electric corona discharge; electrohydrodynamic lifter; lifter configuration; negative corona wire; reactive force analysis; Corona; Electrodes; Foot; Iron; Corona discharge; Electrohydrodynamic flow; lifter;
fLanguage
English
Publisher
ieee
Conference_Titel
Industry Applications Society Annual Meeting (IAS), 2011 IEEE
Conference_Location
Orlando, FL
ISSN
0197-2618
Print_ISBN
978-1-4244-9498-9
Type
conf
DOI
10.1109/IAS.2011.6074272
Filename
6074272