DocumentCode
230077
Title
3D steady-state thermal load analysis of the bus-bar in large-scale generator with evaporative cooling system
Author
Jinxiu Chen ; Haihong Dong ; Lin Ruan
Author_Institution
Inst. of Electr. Eng., Beijing, China
fYear
2014
fDate
22-25 Oct. 2014
Firstpage
2365
Lastpage
2368
Abstract
In hydro-generator, stator bus bar is a vital electrical part and the overheating problem of it is one of the common accidents in hydro-generator. Based on the characteristics of evaporative cooling technology, reliability of large-scale hydro-generator would be enhanced if applying evaporative cooling technology to the stator bus bar. Because of the complex construction of bus bars, copper loss, as the driving force of self-circulation evaporative cooling system of bus bar, has an uneven and complicated distribution. Firstly, this paper briefly introduces evaporative cooling technology and points out several advantages and research difficulties of evaporative cooling stator bus bar. Secondly, based on theory model of eddy current and the finite element calculation software, 3D steady-state copper losses of a group of bus bars with typical structure are calculated. According to the calculation results, characteristics of thermal load distributions of bus bars with typical structure will be summed up.
Keywords
busbars; cooling; finite element analysis; load distribution; stators; 3D steady-state thermal load analysis; copper loss; eddy current; finite element calculation software; hydro-generator; large-scale generator; self-circulation evaporative cooling system; stator bus bar; Bars; Coolants; Eddy currents; Magnetic fields; Stators; Three-dimensional displays;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Machines and Systems (ICEMS), 2014 17th International Conference on
Conference_Location
Hangzhou
Type
conf
DOI
10.1109/ICEMS.2014.7013901
Filename
7013901