  • Abstract
    We have developed a sensitive and economical method to directly detect particles. The technique, which we term rupture event scanning (REVS), is based on rapidly oscillating a surface to which a particle has been attached. This can be achieved with an acoustic wave device, such as a quartz crystal micro-balance (QCM), coated with particle-specific protein or chemical receptors. As the magnitude of oscillation of the surface is increased, there is increasing acceleration of adherent particles. This in turn results in a larger force exerted by the surface on the particle that ultimately causes rupture of the bonds attaching the particle to the surface. The same piezoelectric device can be used as a very sensitive microphone to detect the acoustic emission produced by bond rupture, which is then converted into an electrical signal. The signal indicates not only the presence of the particle and its affinity for the receptor, but also the number of particles present. The method works in air, water and complex biological fluids, is quantitative over at least six orders of magnitude of particle titer, and in affinity from sub-mM to pM. Sensitivity is in the order of fg/mm2 (10-15 g/mm2) and the entire assay currently takes less than one hour to perform.
  • Keywords
    biochemistry; biosensors; crystal resonators; microbalances; microorganisms; molecular biophysics; patient diagnosis; piezoelectric transducers; proteins; acoustic emission; acoustic wave device; adherent particle acceleration; affinity; air; bond rupture; chemical receptors; clinical diagnosis; complex biological fluids; drug discovery process; electrical signal; entire assay; herpes simplex virus; molecular interactions; number of particles; particle direct detection; particle titer; particle-specific protein; piezoelectric device; quartz crystal biosensors; quartz crystal micro-balance; rupture event scanning; sensitive economical method; surface oscillation magnitude; surface rapid oscillation; very sensitive microphone; viral diagnosis; water; Acceleration; Acoustic emission; Acoustic signal detection; Acoustic waves; Chemicals; Joining processes; Microphones; Piezoelectric devices; Proteins; Surface acoustic wave devices;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Sensors, 2002. Proceedings of IEEE
  • Print_ISBN
    0-7803-7454-1
  • Type

    conf

  • DOI
    10.1109/ICSENS.2002.1037256
  • Filename
    1037256