DocumentCode
2317074
Title
Enhancement of NSLS sextupoles using permanent magnets
Author
Rakowsky, G.
Author_Institution
Brookhaven Nat. Lab., Upton, NY, USA
Volume
5
fYear
2001
fDate
2001
Firstpage
3242
Abstract
The recent upgrade of the NSLS X-Ray Ring energy from 2.584 to 2.8 GeV requires defocusing sextupole fields beyond the operating limits of the present sextupole magnets. We have demonstrated that the required fields can be achieved by addition of permanent magnets to counteract the saturation in the magnet poles. Magnetic measurements on a NSLS sextupole agree with fields predicted by Radia
Keywords
accelerator magnets; electron accelerators; permanent magnets; storage rings; 2.8 GeV; NSLS X-Ray Ring; NSLS sextupole magnets; Radia; defocusing sextupole fields; magnet poles; permanent magnets; Coils; Cooling; Electromagnets; Integral equations; Iron; Linearity; Magnetic variables measurement; Magnetization; Permanent magnets; Undulators;
fLanguage
English
Publisher
ieee
Conference_Titel
Particle Accelerator Conference, 2001. PAC 2001. Proceedings of the 2001
Conference_Location
Chicago, IL
Print_ISBN
0-7803-7191-7
Type
conf
DOI
10.1109/PAC.2001.988071
Filename
988071
Link To Document