DocumentCode
2318501
Title
Non-uniform field breakdown characteristics of SF6 /CF4 mixtures at various pressures
Author
Sung, Heo-Gyung ; Hwang, Cheong-Ho ; Kim, Nam-Ryul ; Huh, Chang-Su
Author_Institution
Dept. of Electr. Eng., Inha Univ., Inchon
fYear
2008
fDate
21-24 April 2008
Firstpage
340
Lastpage
343
Abstract
The breakdown and the corona inception voltages experiments of SF6/CF4 mixtures in non-uniform field were performed. The experiments were carried out under AC, positive and negative standard lightning impulse (SLI) voltages. The point-plane electrode was used to make non-uniform field and gap distance was 3 mm. SF6/CF4 mixtures pressure ranged from 0.1 to 0.5 MPa and the percentage of SF6 and CF4 was 0, 20, 40, 60, 80 and 100%. Under positive SLI the breakdown voltage was increased slowly as pressure increasing but under negative SLI the breakdown voltage was increased slightly as pressure increasing. At low pressure the breakdown voltage of positive and negative SLI was similar. Under AC voltage the breakdown voltage was increased linearly but the corona inception voltage was saturated over 0.2 MPa. This paper suggests elementary data in gas insulated systems.
Keywords
SF6 insulation; corona; electric breakdown; gas insulated switchgear; corona inception voltages; gas insulated systems; nonuniform field breakdown characteristics; point-plane electrodes; pressure 0.1 MPa to 0.5 MPa; standard lightning impulse voltages; AC generators; Breakdown voltage; Corona; Dielectric breakdown; Electric breakdown; Electrodes; Partial discharges; Sulfur hexafluoride; Testing; Voltage measurement; Corona; Dielectric Breakdown; SF6 ;
fLanguage
English
Publisher
ieee
Conference_Titel
Condition Monitoring and Diagnosis, 2008. CMD 2008. International Conference on
Conference_Location
Beijing
Print_ISBN
978-1-4244-1621-9
Electronic_ISBN
978-1-4244-1622-6
Type
conf
DOI
10.1109/CMD.2008.4580297
Filename
4580297
Link To Document