Title
Transformer condition assessment via oil quality parameters and DGA
Author
Moradi, M. ; Gholami, A.
fYear
2008
fDate
21-24 April 2008
Firstpage
993
Lastpage
999
Abstract
Mineral based dielectric fluids are widely used in power and distribution transformers worldwide. Also many transformers in power system utilizations approach their end life time. Oils can be a good tool for transformer diagnostics. A survey of more than 300 transformers in Iranian industries has been run and different oil parameters and also gas chromatography results (DGA) have been studied.
Keywords
fault diagnosis; transformer oil; transformer testing; DGA; Iran; distribution transformers; gas chromatography results; oil quality parameters; power system utilization; power transformers; transformer condition assessment; transformer diagnostics; Carbon dioxide; Dissolved gas analysis; Electrical equipment industry; Gas chromatography; Gas insulation; Hydrogen; Oil insulation; Petroleum; Power transformer insulation; Power transformers; Dielectric fluids; mineral oils; oil quality; power transformer diagnostics;