• DocumentCode
    2349307
  • Title

    Image registration of MR and PET based on surface matching and principal axes fitting

  • Author

    Yan, Michelle X H ; Karp, Joel S.

  • Author_Institution
    Pennsylvania Univ., Philadelphia, PA, USA
  • Volume
    4
  • fYear
    1994
  • fDate
    30 Oct-5 Nov 1994
  • Firstpage
    1677
  • Abstract
    We present a surface based image registration algorithm, which uses a combination of minimization of average point-to-surface distance and iterative principal axes fitting (IPAF). MR and PET brain contours are automatically selected from their intensity histograms, such that the separability of object and background is maximized. Cubic B-spline surface is introduced to represent brain surface with few parameters. Its use allows us to accurately compute the point-to-surface distance and the gradient of the distance with respect to registration parameters. As a result, effective distance minimization could be achieved by using a gradient descent algorithm if it is not trapped at a poor local minimum. To prevent being trapped, IPAF algorithm is developed to provide a good initial solution. In addition, it greatly speeds up the registration procedure. The entire procedure is fully automated and is fast enough for routine clinical use. Its performance has been tested using 3D phantom and patient data
  • Keywords
    biomedical NMR; brain; feature extraction; image registration; iterative methods; medical image processing; positron emission tomography; splines (mathematics); 3D phantom data; MR; PET; average point-to-surface distance; background; brain contours; cubic B-spline surface; effective distance minimization; gradient descent algorithm; intensity histograms; iterative principal axes fitting; minimization; object; patient data; principal axes fitting; routine clinical use; surface based image registration algorithm; surface matching; Brain; Histograms; Image registration; Imaging phantoms; Iterative algorithms; Minimization methods; Positron emission tomography; Spline; Surface fitting; Testing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium and Medical Imaging Conference, 1994., 1994 IEEE Conference Record
  • Conference_Location
    Norfolk, VA
  • Print_ISBN
    0-7803-2544-3
  • Type

    conf

  • DOI
    10.1109/NSSMIC.1994.474741
  • Filename
    474741