    Effect of scatter from radioactivity outside of the field of view in 3D PET

  • Author

    Sossi, V. ; Barney, JS ; Harrison, R. ; Moisan, C. ; Ruth, TJ

  • Author_Institution
    British Columbia Univ., Vancouver, BC, Canada
  • Volume
    4
  • fYear
    1994
  • fDate
    30 Oct-5 Nov 1994
  • Firstpage
    1614
  • Abstract
    The contribution of the scattered events originating from radioactivity outside the tomograph field of view (ROFOV) is treated differently by different scatter correction algorithms. The authors have evaluated the amount of scatter originating from ROFOV with measurements and Monte Carlo calculations, its axial and transaxial distribution in two energy windows for direct and a subset of oblique planes in 3D PET. Nonuniform distributions were observed with the total contribution found to be non-negligible when the amount of radioactivity OFOV was comparable to the radioactivity in the FOV
  • Keywords
    Monte Carlo methods; medical image processing; positron emission tomography; radioactivity; 3D PET; Monte Carlo calculations; axial distribution; energy windows; medical diagnostic imaging; nonuniform distributions; nuclear medicine; oblique planes; radioactivity outside field of view; scatter correction algorithms; scatter effect; tomograph field of view; transaxial distribution; Approximation algorithms; Convolution; Detectors; Energy measurement; Event detection; Hospitals; Iterative algorithms; Iterative methods; Positron emission tomography; Scattering;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium and Medical Imaging Conference, 1994., 1994 IEEE Conference Record
  • Conference_Location
    Norfolk, VA
  • Print_ISBN
    0-7803-2544-3
  • Type

    conf

  • DOI
    10.1109/NSSMIC.1994.474754
  • Filename
    474754