• DocumentCode
    2355122
  • Title

    P2H-4 In Vivo Imaging of Coagulated Tissue

  • Author

    Siebers, Stefan ; Scheipers, Ulrich ; Ashfaq, Mohammad ; Hansler, Johannes ; Frieser, Markus ; Strobel, Deike ; Hahn, Eckhart ; Ermert, Helmut

  • Author_Institution
    Inst. of High Frequency Eng., Ruhr-Univ., Bochum
  • fYear
    2006
  • fDate
    2-6 Oct. 2006
  • Firstpage
    1762
  • Lastpage
    1765
  • Abstract
    In this paper first results from a clinical study on imaging thermally coagulated tissue using a system for automated tissue characterization are presented. Complex baseband ultrasound data have been acquired during therapeutic treatments of liver tumors. The current study comprises 11 cases. For data acquisition, a conventional diagnostic ultrasound scanner was used. As a therapeutic device, a clinical approved radio-frequency (RF-) ablation device was chosen. Ultrasonic imaging was done prior to, during and after the treatment session intermittently. Acquired data were stored on an external PC and subdivided into numerous regions of interest (ROI). For each ROI, a set of tissue characterizing spectral and texture features was calculated. The best feature set was processed by the classification system. As training data, feature vectors have been calculated from ROIs representing definitely non coagulated and coagulated liver tissue. Classification was done by calculating maximum likelihood measures for each ROI. Likelihood maps hence obtained showed minima in actually coagulated areas. Starting with the minimum in the likelihood map, a region growing algorithm was used to threshold the maps and to convert them into binary images. Classification was done by total cross validation over cases. The best feature set was found by sequential forward selection and included attenuation, full width at half maximum, maximal correlation coefficient from cooccurrence matrices and gray level nonuniformity from gray level run length matrices. Sensitivity and specificity were determined as a quality measure of the classification results and yielded 0.87plusmn0.09 and 0.96plusmn0.03, respectively
  • Keywords
    biomedical ultrasonics; coagulation; image classification; image segmentation; liver; radiation therapy; tumours; ultrasonic imaging; coagulated tissue; cross validation; image classification; image conversion; liver tumors; map thresholding; ultrasound imaging; Attenuation; Baseband; Data acquisition; Image converters; In vivo; Liver neoplasms; Matrix converters; Radio frequency; Training data; Ultrasonic imaging;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Ultrasonics Symposium, 2006. IEEE
  • Conference_Location
    Vancouver, BC
  • ISSN
    1051-0117
  • Print_ISBN
    1-4244-0201-8
  • Electronic_ISBN
    1051-0117
  • Type

    conf

  • DOI
    10.1109/ULTSYM.2006.443
  • Filename
    4152299