Abstract
A special signal processing method (order analysis) allows well-defined conclusions from accelerometer measurements on electrical drives regarding the reasons of structure-borne and airborne sound. In this paper an analysis of acceleration signals of an 5 kW induction machine is presented. The special feature is that a projection of sound curves is included in this analysis. Thus it is possible to assign an oscillation excitation to harmonics attributed to the machine design or harmonics of the feeding frequency converter
Keywords
accelerometers; design engineering; harmonic analysis; induction motor drives; oscillations; power convertors; signal processing; structural acoustics; 5 kW; acceleration signals; accelerometer measurements; airborne sound; electrical drive systems; frequency converter; induction machine; oscillation excitation; signal processing method; sound curves; structure-borne sound; Acceleration; Accelerometers; Electric variables measurement; Forging; Frequency conversion; Performance evaluation; Signal analysis; Signal processing; Velocity measurement; Vibration measurement;