• DocumentCode
    2356095
  • Title

    P3C-4 Motion Compensated Beamforming in Synthetic Aperture Vector Flow Imaging

  • Author

    Jensen, Jorgen Arendt ; Oddershede, Niels

  • Author_Institution
    Center for Fast Ultrasound Imaging, Tech. Univ. of Denmark, Lyngby
  • fYear
    2006
  • fDate
    2-6 Oct. 2006
  • Firstpage
    2027
  • Lastpage
    2031
  • Abstract
    In synthetic aperture imaging the beamformed data from a number of emissions are summed to create dynamic focusing in transmit. This makes the method susceptible to motion, which is especially the case for the synthetic aperture flow estimation method, where large movements are expected. In this paper, these motion effects are considered. A number of Field II simulations of a single scatterer moving at different velocities are performed both for axial and lateral velocities from 0 to 1 m/s. Data are simulated at a pulse repetition frequency of 5 kHz. The signal-to-noise ratio (SNR) of the beamformed response from the scatterer at all velocities is compared to that of a stationary scatterer. For lateral movement, the SNR drops almost linearly with velocity to -4 dB at 1 m/s, while for axial movement the SNR drop is largest, when the scatterer moves a quarter of a wavelength between emissions. Here the SNR is -10 dB compared to the stationary scatterer. A 2D motion compensation method for synthetic aperture vector flow imaging is proposed, where the former vector velocity estimate is used for compensating the beamforming of new data. This method is tested on data from an experimental flow rig acquired using our RASMUS experimental ultrasound scanner and a 5.5 MHz linear array transducer. A 11.25 mus non-linear chirp is used as excitation and the data from 128 emissions is used for estimating the flow direction and magnitude at a profile across the tube. The measurement was conducted at a flow angle of 60deg with respect to the axial direction and a peak velocity of 0.1 m/s sampled at a pulse repetition frequency of 1 kHz. The mean bias across the profile was -8.4 % with respect to the peak velocity and the mean standard deviation was 12.2 % prior to compensation. When the proposed compensation was applied a mean bias of -3.6 % and a mean standard deviation of 2.8 % was seen
  • Keywords
    biological techniques; biomedical ultrasonics; blood flow measurement; motion compensation; 0 to 1 m/s; 1 kHz; 11.25 mus; 2D motion compensation method; 5 kHz; 5.5 MHz; Field II simulations; RASMUS ultrasound scanner; beamforming; flow direction; signal-to-noise ratio; synthetic aperture imaging; vector flow imaging; Array signal processing; Focusing; Frequency; Motion compensation; Motion estimation; Pulse measurements; Scattering; Signal to noise ratio; Ultrasonic imaging; Vectors;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Ultrasonics Symposium, 2006. IEEE
  • Conference_Location
    Vancouver, BC
  • ISSN
    1051-0117
  • Print_ISBN
    1-4244-0201-8
  • Electronic_ISBN
    1051-0117
  • Type

    conf

  • DOI
    10.1109/ULTSYM.2006.490
  • Filename
    4152346