• DocumentCode
    2357345
  • Title

    P3H-5 Adaptive Beam Steering for Improved Imaging of Carotid Sinus

  • Author

    Hasegawa, Hideyuki ; Mashiyama, Takashi ; Kanai, Hiroshi

  • Author_Institution
    Graduate Sch. of Eng., Tohoku Univ., Sendai
  • fYear
    2006
  • fDate
    2-6 Oct. 2006
  • Firstpage
    2182
  • Lastpage
    2185
  • Abstract
    Recently, cardiovascular disease has become the second most common cause of death in Japan following malignant neoplasm formation. Therefore, it is necessary to diagnose atherosclerosis during its early stages because atherosclerosis is one of the main causes of cardiovascular diseases. The carotid sinus is a site that is easily affected by atherosclerosis [C. K. Zarins et al.: Circ. Res. 53 (1983) 502]; therefore, the diagnosis of this disease at this site is important [S. C. Nicholls et at: Stroke 20 (1989) 175], However, it is difficult to accurately diagnose atherosclerosis in the carotid sinus in the long-axis plane, which is parallel to the axis of the vessel, using conventional linear scanning because the carotid sinus is not flat along the axis of the vessel, and the ultrasonic beams used in linear scanning are perpendicular to the arterial wall in a limited region. Echoes from regions that are not perpendicular to the ultrasonic beams are very weak and the arterial wall in such regions is hardly recognized in a B-mode image. In this study, the position of the arterial wall was predetermined on the basis of the B-mode image obtained by conventional linear scanning, then ultrasonic beams were transmitted again so that all beams were almost perpendicular to the arterial wall. In basic experiments, a nonflat object made of silicone rubber was measured and it was shown that it is possible to image a nonflat object over the entire scanned area using the proposed beam steering method. Furthermore, in in vivo experiments, the intima-media complex was imaged over the entire scanned area at the carotid sinus
  • Keywords
    beam steering; biomedical ultrasonics; blood vessels; cardiovascular system; patient diagnosis; ultrasonic imaging; B-mode image; adaptive beam steering; arterial wall; atherosclerosis; cardiovascular disease; carotid sinus; conventional linear scanning; intima-media complex; malignant neoplasm formation; nonflat object; silicone rubber; ultrasonic beams; ultrasonic imaging; Area measurement; Arteries; Atherosclerosis; Beam steering; Cancer; Cardiac disease; Cardiovascular diseases; Image recognition; Neoplasms; Rubber;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Ultrasonics Symposium, 2006. IEEE
  • Conference_Location
    Vancouver, BC
  • ISSN
    1051-0117
  • Print_ISBN
    1-4244-0201-8
  • Electronic_ISBN
    1051-0117
  • Type

    conf

  • DOI
    10.1109/ULTSYM.2006.550
  • Filename
    4152406