DocumentCode
2362553
Title
Hazard-based safety standard comparison between ECMA 287, IEC 60950-1, IEC 60065
Author
Wang, Zenon ; Hsu, Y.H. ; Nute, Rich
fYear
2005
fDate
3-4 Oct. 2005
Firstpage
75
Lastpage
82
Abstract
ECMA TC 12 had created the draft of ECMA 287 in December 2002 and provided it to IEC TC 108 with items that does not reach consensus. ECMA 287 considers safety evaluation under ITE and AV scope and may differ from current requirements described in the safety standards IEC 60950-1:2001 and IEC 60065:2001. In this article, we focus on the things in ECMA 287 that are new and will require users of IEC 60950-1 and IEC 60065 to change the way they investigate products.
Keywords
IEC standards; electrical safety; electronic products; health hazards; AV; ECMA 287; ECMA TC 12; European computer manufacturers association; IEC 60065 standard; IEC 60950-1 standard; IEC TC 108; ITE; electronic equipment; hazard; product investigation; safety standard; Capacitors; Circuits; Computer aided manufacturing; Humans; IEC standards; Product safety; Protection; Safety devices; Videos; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Product Safety Engineering, 2005 IEEE Symposium on
Print_ISBN
0-7803-9350-3
Type
conf
DOI
10.1109/PSES.2005.1529526