DocumentCode
236420
Title
Establishment of RF attenuation standard in the frequency range of 30 GHz to 50 GHz at NMIJ
Author
Widarta, Anton ; Katou, Yoshihiro
Author_Institution
Nat. Metrol. Inst. of Japan (NMIJ), Nat. Inst. of Adv. Ind. Sci. & Technol. (AIST), Tsukuba, Japan
fYear
2014
fDate
24-29 Aug. 2014
Firstpage
492
Lastpage
493
Abstract
Establishment of RF attenuation standard in the frequency range of 30 GHz to 50 GHz conducted in NMIJ is described. Measurement system is constructed by adopting the simple and high stable IF receiver technique using a resistive step-attenuators, as an IF attenuation reference standard operated at 30 MHz and a general-purpose receiver, as a level detector. Traceability of the system is ensured by performing periodic calibration to the IF attenuation reference standard at 30 MHz using the NMIJ Primary Attenuation Standard system based on the voltage ratio of the IVD. The dynamic range of the system is expected to be more than 80 dB.
Keywords
attenuation measurement; attenuators; calibration; measurement standards; measurement systems; microwave receivers; millimetre wave receivers; IF attenuation reference standard; RF attenuation standard; calibration; frequency 30 GHz to 50 GHz; general-purpose receiver; level detector; measurement standards; measurement system; resistive step-attenuators; traceability; Attenuation; Attenuation measurement; Attenuators; Isolators; Radio frequency; Receivers; Standards; Attenuation; measurement standards; measurement uncertainty; microwave; milliwave; precision measurements;
fLanguage
English
Publisher
ieee
Conference_Titel
Precision Electromagnetic Measurements (CPEM 2014), 2014 Conference on
Conference_Location
Rio de Janeiro
ISSN
0589-1485
Print_ISBN
978-1-4799-5205-2
Type
conf
DOI
10.1109/CPEM.2014.6898474
Filename
6898474