• DocumentCode
    2364565
  • Title

    Fault Tolerant Field Oriented Control of the Induction Motor for Loss of One Inverter Phase

  • Author

    Saleh, Amr ; Pacas, Mario ; Shaltout, Adel

  • Author_Institution
    Inst. of Power Electron. & Electr. Drives, Siegen Univ.
  • fYear
    2006
  • fDate
    6-10 Nov. 2006
  • Firstpage
    817
  • Lastpage
    822
  • Abstract
    This paper presents a fault tolerant strategy for the problem of loss of one phase in a field oriented controlled three phase induction motor. The proposed solution, rather than previously suggested solutions, is a control strategy in the single phase mode of operation of the induction motor. The suggested strategy can be applied to both delta and star connected motors. Average torque equivalent to the required reference torque is obtained. Tests are applied experimentally on a 10 kW motor to validate the proposed strategy. Limitation due to maximum permissible current is also discussed
  • Keywords
    fault tolerance; induction motors; invertors; machine testing; machine vector control; torque; 10 kW; average torque equivalent; delta connected motors; fault tolerant field oriented control; induction motor; inverter phase; single phase mode; star connected motors; Circuit faults; DC motors; Fault tolerance; Fluctuations; Induction motors; Inverters; Leg; Stators; Torque; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    IEEE Industrial Electronics, IECON 2006 - 32nd Annual Conference on
  • Conference_Location
    Paris
  • ISSN
    1553-572X
  • Print_ISBN
    1-4244-0390-1
  • Type

    conf

  • DOI
    10.1109/IECON.2006.347580
  • Filename
    4153034