DocumentCode
2365418
Title
Computer modelling of heart rate and blood pressure
Author
Whittam, AM ; Clayton, Rh ; Lord, SW ; McComb, JM ; Murray, A.
Author_Institution
Dept. of Regional Med. Phys., Freeman Hosp., Newcastle upon Tyne, UK
fYear
1998
fDate
13-16 Sep 1998
Firstpage
149
Lastpage
152
Abstract
A computer model of the cardiovascular system which models beat-to-beat changes in heart period, systolic pressure, diastolic pressure and the arterial time constant has been studied. The original model, produced by de Boer et al. (1987), was developed with limited data. The authors have shown that in some situations the model may be highly inaccurate, but that it is possible to adapt the model to fit a wide range of data move accurately. From 7 normal subjects the authors recorded a single channel ECG, blood pressure non-invasively using a Finapres monitor, and depth of respiration. The mean values of RR interval, systolic and diastolic pressure, arterial time constant, and baroreflex sensitivity were calculated. The model was produced using LabView, a graphical programming environment. The first implementation of the model used the clinical values calculated the constants specified by de Boer, and the respiration signal the amplitude of which was set so that the power in the high frequency (0.15-0.4 Hz) systolic pressure peak from the model matched that of the real data. The model output was compared with the recorded data for the low frequency (0.04-0.15 Hz) and high frequency spectral peaks of RR interval and low frequency spectral peak of systolic pressure. In some subjects the model outputs were within a factor of 2 but a wide range was obtained up to a factor of 60 for a young healthy subject with high baroreflex sensitivity. It was possible to adapt the model to fit the range of all normal data to within a factor of 8 for the RR and systolic pressure spectral peaks. Overall, the model fitted the high frequency peaks best, with the adaptation having the greatest effect on the low frequency peaks
Keywords
blood pressure measurement; cardiovascular system; digital simulation; electrocardiography; medical diagnostic computing; physiological models; 0.04 to 0.4 Hz; Finapres monitor; LabView; RR interval; arterial time constant; baroreflex sensitivity; beat-to-beat changes; blood pressure; computer modelling; diastolic pressure; graphical programming environment; heart period; heart rate; respiration depth; single channel ECG; systolic pressure; Baroreflex; Biomedical monitoring; Blood pressure; Cardiology; Cardiovascular system; Electrocardiography; Frequency; Heart rate; Instruments; Time series analysis;
fLanguage
English
Publisher
ieee
Conference_Titel
Computers in Cardiology 1998
Conference_Location
Cleveland, OH
ISSN
0276-6547
Print_ISBN
0-7803-5200-9
Type
conf
DOI
10.1109/CIC.1998.731754
Filename
731754
Link To Document