• DocumentCode
    236639
  • Title

    Power calibration system based on Josephson sampling voltmeter

  • Author

    Mun-Seog Kim ; Wan-Seop Kim ; Young Gyun Kim ; Yonuk Chong ; Kyu-Tae Kim ; Po Gyu Park

  • Author_Institution
    Korea Res. Inst. of Stand. & Sci., Daejeon, South Korea
  • fYear
    2014
  • fDate
    24-29 Aug. 2014
  • Firstpage
    738
  • Lastpage
    739
  • Abstract
    This paper describes system setup, based on a Josephson sampling voltmeter for precision power calibration. The waveforms generated by voltage and current sources, which are applied to a power meter under test, are transformed to 1-V level voltage signals and measured by a single Josephson voltmeter with a uncertainty (k = 2) less than 0.5 μV/V.
  • Keywords
    calibration; constant current sources; measurement uncertainty; power measurement; power meters; voltage measurement; voltmeters; waveform generators; Josephson sampling voltmeter; current source; measurement uncertainty; power meter under test; precision power calibration system; voltage 1 V; voltage source; waveform generation; Calibration; Current measurement; Measurement uncertainty; Semiconductor device measurement; Standards; Voltage measurement; Voltmeters; Power standard; programmable Josephson voltage standard; quantum voltmeter; sampling measurement; uncertainty;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements (CPEM 2014), 2014 Conference on
  • Conference_Location
    Rio de Janeiro
  • ISSN
    0589-1485
  • Print_ISBN
    978-1-4799-5205-2
  • Type

    conf

  • DOI
    10.1109/CPEM.2014.6898597
  • Filename
    6898597