• DocumentCode
    237302
  • Title

    Pose and position calibration of laser displacement sensor in aspheric measurement

  • Author

    Bing Li ; Xiang Wei ; Lijiao Jia ; Zhuangde Jiang ; Lei Chen

  • Author_Institution
    State Key Lab. for Manuf. Syst. Eng., Xi´an Jiaotong Univ., Xi´an, China
  • fYear
    2014
  • fDate
    27-29 Nov. 2014
  • Firstpage
    104
  • Lastpage
    109
  • Abstract
    This paper suggest a model to calibration the pose and position of laser displacement sensor. In practice, the direction of laser and motion axis can´t completely overlap. It will cause some errors in measurement. And it will have a great influence on the measurement result, especially in the large-scale measurement. Through the calibration method of this paper, the error cause by pose and position will be reduced in some extend. The calibration method and the evaluation result are described in detail in the paper.
  • Keywords
    calibration; displacement measurement; measurement by laser beam; measurement errors; aspheric measurement; laser displacement sensor; measurement errors; pose calibration; position calibration; Accuracy; Calibration; Charge coupled devices; Laser modes; Measurement by laser beam; Standards; Calibration; Laser displacement sensor; Pose and position;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Mecatronics (MECATRONICS), 2014 10th France-Japan/ 8th Europe-Asia Congress on
  • Conference_Location
    Tokyo
  • Type

    conf

  • DOI
    10.1109/MECATRONICS.2014.7018590
  • Filename
    7018590