    Human feasibility study of hemodynamic monitoring via continuous intrathoracic impedance monitoring

  • Author

    Hettrick, Douglas A. ; Schwartzman, David

  • Author_Institution
    Cardiac Rhythm & Disease Manage. Medtronic, Inc., Mounds View, MN, USA
  • fYear
    2009
  • fDate
    3-6 Sept. 2009
  • Firstpage
    4611
  • Lastpage
    4614
  • Abstract
    The ultimate hemodynamic sensor for an implantable device would provide information about cardiovascular performance including systolic function, diastolic function, preload, and afterload. We examined the potential clinical utility of simultaneous measurement of left ventricular pressure and continuous intrathoracic impedance in a group of 20 patients undergoing acute intravenous ablation for atrial fibrillation. Following baseline measurements of traditional left ventricular (LV) conductance volume (control), LV pressure and conductance measurement were repeated using alternate impedance stimulation and sensing vectors that encompassed combinations of the lung, left ventricle, right ventricle and left atrium, respectively. Various relative indices of LV function, including end systolic pressure to volume (conductance) ratio, end diastolic pressure to volume (conductance) ratio, and preload recruitable stroke work (analog) were derived by combining real-time pressure and conductance. The raw morphometry of the LV vector seemed to most closely resemble the gold standard LV conductance volume. For this vector, strong linear correlations between LV pressure and end systolic conductance (r = 3D0.84plusmn0.14), end diastolic conductance (r = 3D0.78plusmn0.10) and preload recruitable stroke work analog (r = 3D0.93plusmn0.05) were observed. The LV vector provides a robust continuous intracardiac hemodynamic signal that may be useful for quantifying cardiovascular function.
  • Keywords
    bioelectric phenomena; blood flow measurement; blood pressure measurement; cardiovascular system; electric impedance measurement; patient monitoring; LV function; LV pressure measurement; LV vector; acute intravenous ablation; atrial fibrillation; baseline measurements; cardiovascular function quantification; continuous intracardiac hemodynamic signal; continuous intrathoracic impedance monitoring; end diastolic pressure to volume ratio; end systolic conductance measurement; end systolic pressure to volume ratio; hemodynamic monitoring; hemodynamic sensor; impedance stimulation; left ventricular pressure; potential clinical utility; preload recruitable stroke work; raw morphometry; real-time conductance; real-time pressure; traditional left ventricular conductance volume; Aged; Atrial Fibrillation; Cardiography, Impedance; Feasibility Studies; Female; Hemodynamics; Humans; Linear Models; Male; Middle Aged; Monitoring, Ambulatory; Signal Processing, Computer-Assisted; Ventricular Pressure;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 2009. EMBC 2009. Annual International Conference of the IEEE
  • Conference_Location
    Minneapolis, MN
  • ISSN
    1557-170X
  • Print_ISBN
    978-1-4244-3296-7
  • Electronic_ISBN
    1557-170X
  • Type

    conf

  • DOI
    10.1109/IEMBS.2009.5332461
  • Filename
    5332461