• DocumentCode
    2382178
  • Title

    Problems in the use of Norton equivalent models for single-phase nonlinear loads

  • Author

    Rylander, Matthew ; Grady, W. Mack

  • Author_Institution
    Dept. of Electr. & Comput. Eng., Univ. of Texas, Austin, TX, USA
  • fYear
    2010
  • fDate
    25-29 July 2010
  • Firstpage
    1
  • Lastpage
    7
  • Abstract
    This paper illustrates the problems associated with using Norton equivalent models to represent single-phase nonlinear loads. The study is conducted with a specially-developed harmonics testing station that uses feedback to drive the load voltage to a desired target waveform. We apply various voltage waveshapes with 5% THDv to several types of single-phase nonlinear loads which allow us to compute the Norton parameters. The test results show that the Norton equivalent model for a nonlinear load is not unique and varies significantly with applied voltage waveshape.
  • Keywords
    power system harmonics; Norton equivalent models; THD; applied voltage waveshape; harmonics testing station; single-phase nonlinear loads; Harmonics; Nonlinear load model; Norton equivalent;